- 360 Grad Bild (HTML Code): <a class="Magic360" data-options="columns: 73; rows: 1;"><img src="images/stories/produkte/ACA/360-webp/01.webp" /></a>
- Untersuchung von:
- Eigenschaft: paper
- Eigenschaft: board
- Eigenschaft: plastic film
- Vorteile:
- Vorteil: non- destructive measurement without combustion
- Vorteil: quantitative determination of individual fillers
- Vorteil: availability of the results within seconds (approx. 60 sec.)
- Vorteil: high accuracy of measurements
- Vorteil: easy handling (self-explanatory operation)
- Vorteil: results independent of operator
- Vorteil: easy portable (in a trolley)
- Vorteil: savings in time and energy (compared to combustion)
- Vorteil: optimal process control due to instant availability of measuring results
- Vorteil: efficient calibration of online ash sensors (especially in case of frequent grade changes)
- Produktbeschreibung:
With the combustion method according to ISO 2144, DIN 54370, TAPPI T 413 and 211, which is traditionally applied in the paper industry, the total content and a few selected individual fillers can only be determined through an extremely time- and energy-consuming and in routine operation relatively inaccurate combustion of the samples at different temperatures (+/- 5%, operator dependent!). The combustion method is also disadvantageous due to its destructive measuring procedure.
By the use of the emtec ACA Ash Content Analyzer with its new and innovative measuring principle the total ash content (fillers and pigments), but also the percentage content of the typical fillers in the paper industry can be determined within seconds without combustion of the samples, i.e., non-destructive.
The quick measuring procedure leads to an almost instant availability of measuring results and therefore allows for an indeed immediate reaction to changes in the process:
- Immense material savings can be achieved through the reduction of process fluctuations
- The consumption of fillers can be reduced, as the immediate availability of results and the high accuracy of the ACA enables the narrowing down of the specifications for the filler content in the finished product, resulting in a much more efficiently organized process optimization (e.g. retention optimization)
- Costs for energy of the combustion process can be saved. Thus, the use of the new measuring device guarantees a fast "return on investment" by a substantial reduction of costs in material, time, and energy
- Anwender: Chemical suppliers, Paper producers , Paper converters, Board producers , Corrugated board producers , Pulp producers, Universities & Institutes, Producers of pigments
- Anwendungsgebiete: Process optimization, Product optimization, R&D, Incoming control, Quality assurance, Complaint management, Troubleshooting
- Ergebnisse:
- Wert:
% value
, Beschreibung:Total filler content
- Wert:
Individual fillers (%)
, Beschreibung:Calcium carbonate, Titan dioxide, Kaolin/Talcum, Barium sulfate, Iron oxide
- Wert:
- technische Daten:
- Titel: device dimensions (H x W x D), Wert: approx. 43.1 x 32.1 x 26.1 cm (folded), Beschreibung: approx. 43.1 x 32.1 x 38.3 cm (unfolded)
- Titel: weight, Wert: approx. 15 kg
- Titel: measuring principle , Wert: X-ray fluorescence analysis
- Titel: radiation source, Wert: X-ray tube (gold, 10 kV, 5 μA)
- Titel: accuracy of measurement, Wert: approx. ≤ ±1-2 % (abs.)
- Titel: measurement time, Wert: approx. 60 sec
- Titel: grammage max., Wert: 1000 g/m2
- Titel: power supply, Wert: 100 - 240 VAC (50/60 Hz)
- Downloads:
- Beschriftung : Leaflet (English), Link: images/stories/infomaterial/02_ACA/01_Leaflet/emtec_ACA_leaflet_en.pdf
- Beschriftung : Leaflet (French), Link: images/stories/infomaterial/02_ACA/01_Leaflet/emtec_ACA_leaflet_fr.pdf
- Beschriftung : Leaflet (Spanish), Link: images/stories/infomaterial/02_ACA/01_Leaflet/emtec_ACA_leaflet_es.pdf
- Beschriftung : Leaflet (Italian), Link: images/stories/infomaterial/02_ACA/01_Leaflet/emtec_ACA_leaflet_it.pdf
- Beschriftung : Leaflet (Turkish), Link: images/stories/infomaterial/02_ACA/01_Leaflet/emtec_ACA_leaflet_tr.pdf
- Beschriftung : Leaflet (Swedish), Link: images/stories/infomaterial/02_ACA/01_Leaflet/emtec_ACA_leaflet_se.pdf
- Beschriftung : Leaflet (Japanese), Link: images/stories/infomaterial/02_ACA/01_Leaflet/emtec_ACA_leaflet_jp.pdf
- Beschriftung : Leaflet (Chinese), Link: images/stories/infomaterial/02_ACA/01_Leaflet/emtec_ACA_leaflet_zh.pdf
- Beschriftung : Leaflet (Russia), Link: images/stories/infomaterial/02_ACA/01_Leaflet/emtec_ACA_leaflet_ru.pdf
- Beschriftung : Leaflet (Polish), Link: images/stories/infomaterial/02_ACA/01_Leaflet/emtec_ACA_leaflet_pl.pdf
- Beschriftung : Booklet (English), Link: images/stories/infomaterial/02_ACA/02_Booklet/emtec_ACA_Ash_Content_Analyzer_booklet_en.pdf
- Applikationsbeispiele inaktiv: Nein
- Applikationsbeispiele: Evaluation of decor paper with the ACA: what fillers and what amount of each is in the paper
- Videos:
- Vorschaubild:
, Videodatei: images/stories/infomaterial/02_ACA/05_Produktvideos/10_Internet/aca-1080.mp4
- Vorschaubild:
- Zubehör inaktiv: Ja
- verwandte Produkte: CAS touch! - Charge Analyzing System, EST 12 - Surface and Sizing Tester, FPA touch! - Fiber Potential Analyzer, FPO - Fiber Potential Analyzer online, PDA.C 02 MST - Module Standard, Sample Punch
- 360 Grad Bild (HTML Code): <a class="Magic360" data-options="columns: 72; rows: 1;"><img src="images/stories/produkte/CAS3/360-webp/01.webp" /></a>
- Untersuchung von:
- Eigenschaft: particle charge in the fiber
- Vorteile:
- Vorteil: smaller and significantly lighter than comparable devices
- Vorteil: comfortable transport (carry-on-luggage size)
- Vorteil: state-of-the-art touch screen (including display of the results and curves)
- Vorteil: external keyboard connectable (via USB or wireless)
- Vorteil: ready to use without assembling of any further components
- Vorteil: compact and robust construction
- Vorteil: can be used as stand-alone device or in connection with a PC
- Vorteil: adaptation to customer specific needs is possible (e.g. manual vs. automatic titration, titration procedures)
- Produktbeschreibung:
Using standard techniques of titration, the CAS touch! determines cationic/anionic and acid/base demands of aqueous charge systems. Modern electronic components enable the high accuracy of measurement. Both, Streaming Potential (mV) and pH can be measured simultaneously, making it possible to easily determine isoelectric and flocculation points of a sample and examine the correlation between pH, titrant demand and streaming potential.
Customer’s choice:
The CAS touch! uses integrated high precision titrators, optionally with 1 or 2 titration systems (CAS-I touch! or CAS-II touch!), while also a version for use with external or hand titration is available to the customer (CAS-E touch!).
Measurement / Result evaluation:
The CAS touch! can be operated via Touch Screen, which displays the data including titration curves, optionally in combination with an external keyboard. Moreover, there is no need to adjust to a new software, as the device can also be used with the common easy-to-handle CAS PC software. The efficient testing procedures implemented in extremely user-friendly PC software make it very easy to handle. Different titration procedures are available: fixed increment titration, dynamic titration and back-titration are selectable from given procedures or are freely configurable. Default standard titration procedures and customer-specific processes can be stored in the CAS touch! via the PC software or Touch Screen. Data can be stored internally as well as externally on an USB flash drive, analyzed with PC software and exported to Excel (only two mouse clicks).
Transport / Assembly:
The low weight device can easily be transported in a carry-on size case, which is especially important for chemical suppliers for customer visits. After unpacking the device and connecting it to the mains voltage, the CAS touch! is ready for starting the measurement! There is no complicated assembly and no tubes are needed.
- Anwender: Chemical suppliers, Paper machine builders, Paper producers , Board producers , Corrugated board producers , Tissue producers, Pulp producers, Universities & Institutes
- Anwendungsgebiete: Process optimization, Process control, Product optimization, R&D, Complaint management, Troubleshooting
- Ergebnisse:
- Wert:
Streaming potential (mV)
- Wert:
pH value
- Wert:
cationic/anionic demand (ml)
- Wert:
particle charge (mV)
- Wert:
- technische Daten:
- Titel: device dimensions, Wert: 17 x 28.5 x 17 cm (W x H x D)
- Titel: device weight , Wert: approx 3.30 - 4.25 kg (depending on model)
- Titel: min. sample volume, Wert: 10 ml
- Titel: maximum conductivity of the sample, Wert: 11 mS/cm (selective sample preparation can be measured for samples with significantly higher conductivity)
- Titel: dosing system, Wert: selectable final criteria: - pH: 0-14 - mV: -5000 to +5000 - 0-25 ml anionic/cationic demand - 0-25 ml acid/basic demand
- Downloads:
- Beschriftung : Leaflet (English), Link: images/stories/infomaterial/09_CAS_touch/01_Leaflet/01_Standard/AFG_CAS_touch_leaflet_en.pdf
- Beschriftung : Leaflet (French), Link: images/stories/infomaterial/09_CAS_touch/01_Leaflet/01_Standard/emtec_CAS_touch_leaflet_fr.pdf
- Beschriftung : Leaflet (Spanish), Link: images/stories/infomaterial/09_CAS_touch/01_Leaflet/01_Standard/emtec_CAS_touch_leaflet_es.pdf
- Beschriftung : Leaflet (Italian), Link: images/stories/infomaterial/09_CAS_touch/01_Leaflet/01_Standard/emtec_CAS_touch_leaflet_it.pdf
- Beschriftung : Leaflet (Turkish), Link: images/stories/infomaterial/09_CAS_touch/01_Leaflet/01_Standard/emtec_CAS_touch_leaflet_tr.pdf
- Beschriftung : Leaflet (Swedish), Link: images/stories/infomaterial/09_CAS_touch/01_Leaflet/01_Standard/emtec_CAS_touch_leaflet_se.pdf
- Beschriftung : Leaflet (Japanese), Link: images/stories/infomaterial/09_CAS_touch/01_Leaflet/01_Standard/emtec_CAS_touch_leaflet_jp.pdf
- Beschriftung : Leaflet (Chinese), Link: images/stories/infomaterial/09_CAS_touch/01_Leaflet/01_Standard/emtec_CAS_touch_leaflet_zh.pdf
- Beschriftung : Leaflet (Russian), Link: images/stories/infomaterial/09_CAS_touch/01_Leaflet/01_Standard/emtec_CAS_touch_leaflet_ru.pdf
- Beschriftung : Leaflet (Polish), Link: images/stories/infomaterial/09_CAS_touch/01_Leaflet/01_Standard/emtec_CAS_touch_leaflet_pl.pdf
- Beschriftung : Booklet (English), Link: images/stories/infomaterial/09_CAS_touch/02_Booklet/Application_booklet_CAS_touch_and_FPA_touch_en.pdf
- Applikationsbeispiele inaktiv: Nein
- Applikationsbeispiele: CAS touch! (cationic demand) and FPA touch! (Zeta Potential) in the process, Process optimization with the CAS touch! (particle charge) and FPA touch! (zeta potential)
- Videos:
- Vorschaubild:
, Videodatei: images/stories/infomaterial/09_CAS_touch/05_Produktvideos/10_Internet/cas-touch-1080.mp4
- Vorschaubild:
- Zubehör inaktiv: Ja
- verwandte Produkte: FPA touch! - Fiber Potential Analyzer, FPO - Fiber Potential Analyzer online
- 360 Grad Bild (HTML Code): <a class="Magic360" data-options="columns: 73; rows: 1;"><img src="images/stories/produkte/DFA/360-webp/01.webp" /></a>
- Untersuchung von:
- Eigenschaft: flocculants, retention agents and various additives
- Vorteile:
- Vorteil: simulation of the dynamic situation in the wet-end range by adjustable stirring profile (defined entry of shear forces) and interchangeable screens, use of customer-specific screens optionally possible
- Vorteil: lightweight construction
- Vorteil: fast and repeatable (automated) measurement sequence
- Vorteil: reproducible and sensitive measurement method
- Vorteil: illustration of the dewatering behavior via graphs
- Vorteil: data storage and evaluation possibilities via the software
- Vorteil: investigation of the interaction of additives on the flocculation process
- Vorteil: setermination of product efficiency in product alternatives
- Vorteil: combination of dewatering and retention measurement in one device, based on the Schopper-Riegler method to measure the dewatering and on the classic dynamic Drainage Yar Method for the determination of the retention (two in one)
- Vorteil: analysis of the performance of flocculation agents, retention aid and diverse other additives
- Produktbeschreibung:
A PC operates the DFA. The user-friendly software controls the measurement and allows a sophisticated analysis and reporting of all results. In order to simulate different process conditions, all relevant data to configure a mixing profile is stored and used for automatic measurements.
The user selects a mixing profile or sets all relevant mixing parameters before starting the measurement. After that, the DFA stirring chamber fills with the fiber suspension. The selected set mixing profile starts to stir the suspension as per set parameters. A dosage of chemical additives during the stirring process is possible to influence the drainage and retention process. Thru the use of audible prompts the user is notified when to introduce any chemicals. A valve opens automatically when the mixing process is finished. Filtration through selected screen starts immediately.
Filtrate is continuously measured with approximately five sample points per second. The quantity of filtrate is shown on a graph as a function of time. The computer software allows displaying different graphs, comparing results, adding all kinds of parameters to graphs or creating comparable graphs. E.g., the quantity of dosed chemicals can be compared to the dehydration velocity. The export of all measurement data into an EXCEL-spread sheet for further analysis and data storage is possible. The instrument also has an integrated pH-measurement.
Retention Measurement:
The DFA system is equipped with the possibility to calculate Total Retention and Filler Retention. A filtrate is produced by the DFA system for determining the retention. Different practical filtration conditions can be simulated with a magnetic valve under the filter and different mixing gears. The filter remains clean by the mixing gear. The user has to enter the filler content or the overall solid content of the filtrate and the sample in the PC and get the total or filler retention by the DFA software.
- Anwender: Chemical suppliers, Paper machine builders, Paper producers , Board producers , Corrugated board producers , Pulp producers, Universities & Institutes
- Anwendungsgebiete: Process optimization, Process control, Product optimization, R&D, Complaint management, Troubleshooting
- Ergebnisse:
- Wert:
Drainage curves (time/filtrate amount)
- Wert:
Overall retention
- Wert:
Filler retention
- Wert:
pH value
- Wert:
- technische Daten:
- Titel: device dimensions, Wert: 18.9 x 25.5 x 50.1 cm (W x D x H)
- Titel: weight, Wert: 17.5 kg
- Titel: power supply, Wert: input voltage: 85 - 264 V AC Frequency: 47 - 63 Hz Consumption maximum: 80W Fuses of the device: 1 x 10 A slow-blow
- Titel: operating condition, Wert: Surrounding: +10°C [+50°F] to +40°C [104°F]; not condensation
- Titel: transport and storage condition, Wert: Surrounding: -10°C [+50°F] to +40°C [+140°F]
- Downloads:
- Beschriftung : Leaflet (English), Link: images/stories/infomaterial/12_DFA/01_Leaflet/AFG_DFA_leaflet_en.pdf
- Applikationsbeispiele inaktiv: Ja
- Zubehör inaktiv: Ja
- verwandte Produkte: CAS touch! - Charge Analyzing System, FPA touch! - Fiber Potential Analyzer
Emtec Electronic masters another milestone in terms of Industry 4.0 and thus brings new perspectives
- 360 Grad Bild (HTML Code): <a class="Magic360" data-options="columns: 73; rows: 1;"><img src="images/stories/produkte/EST/360-webp/01.webp" /></a>
- Untersuchung von:
- Eigenschaft: paper
- Eigenschaft: board
- Vorteile:
- Vorteil: measurement of the converting-relevant parameters surface sizing/surface hydrophobia and surface porosity
- Vorteil: measured parameters help to optimize the converting process and the product quality, for example by adapting the converting process to the quality of the incoming paper or board
- Vorteil: reliable and accurate test results, which help to solve issues in the converting process and with the product quality, where standard test devices are no help
- Vorteil: Stand-alone device (connection to a PC and use with emtec PC software possible)
- Vorteil: small and easy to transport, especially good for chemical suppliers
- Produktbeschreibung:
To make sure that the necessary product quality can be reached, specifications are agreed between paper maker and converter. These specifications are bases on standard test devices, such as Cobb or Gurley. But often it happens that although the quality of the base paper or board is within the agreed specifications, issues with the gluability, printability or coating-ability occur during the converting.
Since gluability, printability and coating-ability mainly depend on surface sizing and surface porosity, information about these two parameters are very important. But the standard test devices are not able to measure them. In comparison to this, the emtec EST is able to measure these two very important surface parameters within the time that is relevant for the converting process and by this helps to ensure a well-running converting process and the right product quality.
- Anwender: Chemical suppliers, Paper producers , Paper converters, Board producers , Board converters, Corrugated board producers , Universities & Institutes
- Anwendungsgebiete: Process optimization, Product optimization, Benchmarking, R&D, Incoming control, Quality assurance, Complaint management, Troubleshooting
- Ergebnisse:
- Wert:
MAX value
, Beschreibung:surface sizing/hydrophobia
- Wert:
t95 value Max
, Beschreibung:surface porosity
- Wert:
- technische Daten:
- Titel: device dimensions, Wert: 25 x 14 x 25 cm (H x W x D)
- Titel: weight, Wert: approx. 4 kg / 8.8 lbs
- Titel: measuring frequencies, Wert: 1 MHz, 2 MHz selectable
- Titel: supply voltage, Wert: 100-240 VAC, 50/60 Hz
- Titel: sample dimension, Wert: 75 x 50 mm
- Downloads:
- Beschriftung : Leaflet (English), Link: images/stories/infomaterial/05_EST/01_Leaflet/emtec_EST12_leaflet_en.pdf
- Beschriftung : Leaflet (French), Link: images/stories/infomaterial/05_EST/01_Leaflet/emtec_EST12_leaflet_fr.pdf
- Beschriftung : Leaflet (Spanish), Link: images/stories/infomaterial/05_EST/01_Leaflet/emtec_EST12_leaflet_es.pdf
- Beschriftung : Leaflet (Italian), Link: images/stories/infomaterial/05_EST/01_Leaflet/emtec_EST12_leaflet_it.pdf
- Beschriftung : Leaflet (Turkish), Link: images/stories/infomaterial/05_EST/01_Leaflet/emtec_EST12_leaflet_tr.pdf
- Beschriftung : Leaflet (Swedish), Link: images/stories/infomaterial/05_EST/01_Leaflet/emtec_EST12_leaflet_se.pdf
- Beschriftung : Leaflet (Japenese), Link: images/stories/infomaterial/05_EST/01_Leaflet/emtec_EST12_leaflet_jp.pdf
- Beschriftung : Leaflet (Chinese), Link: images/stories/infomaterial/05_EST/01_Leaflet/emtec_EST12_leaflet_zh.pdf
- Beschriftung : Leaflet (Russia), Link: images/stories/infomaterial/05_EST/01_Leaflet/emtec_EST12_leaflet_ru.pdf
- Beschriftung : Leaflet (Polish), Link: images/stories/infomaterial/05_EST/01_Leaflet/emtec_EST12_leaflet_pl.pdf
- Beschriftung : Booklet (English), Link: images/stories/infomaterial/05_EST/02_Booklet/01_EN/emtec_EST_Surface_and_Sizing_Tester_booklet_en.pdf
- Applikationsbeispiele inaktiv: Nein
- Applikationsbeispiele: Evaluation of the surface hydrophobia (Cobb60 vs. emtec EST)
- Zubehör inaktiv: Ja
- verwandte Produkte: PDA.C 02 MST - Module Standard
- 360 Grad Bild (HTML Code): <a class="Magic360" data-options="columns: 74; rows: 1;"><img src="images/stories/produkte/MSC/360-webp/01.webp" /></a>
- Untersuchung von:
- Eigenschaft: paper
- Eigenschaft: board
- Vorteile:
- Vorteil: measurement of the converting-relevant parameters surface sizing/surface hydrophobia and surface porosity
- Vorteil: measured parameters help to optimize the converting process and the product quality, for example by adapting the converting process to the quality of the incoming paper or board
- Vorteil: modular system (e.g., Module HVL for tests with high viscous liquids or the Module Standard for tests with low viscous liquids)
- Vorteil: reliable and accurate test results, which help to solve issues in the converting process and with the product quality, where standard test devices are no help
- Vorteil: Module Standard Coating allows measurements with coating color
- Produktbeschreibung:
The PDA.C 02 - Module MSC Standard Coating helps to detect changes in base papers, coating colors, and coated papers, which are not detected by standard test devices, but which can lead issues with the coating-ability during the converting process.
The contact between coating color and base coating paper happens under high shear and pressure pulse, leading to a good simulation of the coating machine applicator.
Pilot coater and machine trials indicate the effects of coating color and base paper variations. The PDA.C 02 provides a tool to explore the causes.
- Anwender: Chemical suppliers, Paper machine builders, Paper producers , Paper converters, Board producers , Board converters, Corrugated board producers , Universities & Institutes
- Anwendungsgebiete: Process optimization, Product optimization, Benchmarking, R&D, Incoming control, Quality assurance, Complaint management, Troubleshooting
- Ergebnisse:
- Wert:
Max value
, Beschreibung:surface sizing/hydrophobia
- Wert:
t95 value
, Beschreibung:surface porosity
- Wert:
- technische Daten:
- Titel: device dimensions, Wert: basic device 42 x 16 x 32 cm (H x W x D) , Beschreibung: Motor Control Unit 11 x 16 x 24 cm (H x W x D)
- Titel: weight, Wert: approx. 16 kg
- Titel: sample dimension, Wert: 75 x 50 mm
- Titel: measuring frequencies, Wert: 1 MHz, 2 MHz selectable
- Titel: first measured value, Wert: approx. 10 ms after liquid contact
- Titel: measurement intervals , Wert: approx. 1 ms
- Titel: data structure, Wert: ASCII file
- Titel: supply voltage, Wert: 115-230 VAC, 50-60 Hz
- Downloads:
- Beschriftung : Leaflet (English), Link: images/stories/infomaterial/04_PDA.C02_alle_Module/03_PDA_MST_C/01_Leaflet/emtec_PDA.C02_MSC_CMA_leaflet_en.pdf
- Applikationsbeispiele inaktiv: Ja
- Zubehör inaktiv: Nein
- Zubehör: OSB - Sample Preparation Device, SPM - Sample Preparation Machine, TCU - Temperature Control Unit
- verwandte Produkte: EST 12 - Surface and Sizing Tester, PDA.C 02 HVL - Module High Viscous Liquids, PDA.C 02 MST - Module Standard
- 360 Grad Bild (HTML Code): <a class="Magic360" data-options="columns: 73; rows: 1;"><img src="images/stories/produkte/MST/360-webp/01.webp" /></a>
- Untersuchung von:
- Eigenschaft: paper
- Eigenschaft: board
- Vorteile:
- Vorteil: measurement of the converting-relevant parameters surface sizing/surface hydrophobia and surface porosity
- Vorteil: easy to handle
- Vorteil: measured parameters help to optimize the converting process and the product quality, for example by adapting the converting process to the quality of the incoming paper or board
- Vorteil: modular system (e.g., Module HVL for tests with high viscous liquids or the Module Standard Coating for tests with coating color)
- Vorteil: reliable and accurate test results, which help to solve issues in the converting process and with the product quality, where standard test devices are no help
- Produktbeschreibung:
To make sure that the necessary product quality can be reached, specifications are agreed between paper maker and converter. These specifications are bases on standard test devices, such as Cobb or Gurley. But often it happens that although the quality of the base paper or board is within the agreed specifications, issues with the gluability, printability or coating-ability occur during the converting.
Since gluability, printability and coating-ability mainly depend on surface sizing and surface porosity, information about these two parameters are very important. But the standard test devices are not able to measure them. In comparison to this, the emtec PDA is able to measure these two very important surface parameters within the time that is relevant for the converting process and by this helps to ensure a well-running converting process and the right product quality.
- Anwender: Chemical suppliers, Paper producers , Paper converters, Board producers , Board converters, Corrugated board producers , Universities & Institutes
- Anwendungsgebiete: Process optimization, Product optimization, Benchmarking, R&D, Incoming control, Quality assurance, Complaint management, Troubleshooting
- Ergebnisse:
- Wert:
t95 value
, Beschreibung:surface porosity
- Wert:
MAX value
, Beschreibung:surface sizing/hydrophobia
- Wert:
- technische Daten:
- Titel: device dimensions, Wert: basic device 42 x 16 x 32 cm (H x W x D), Beschreibung: Motor Control Unit 11 x 16 x 24 cm (H x W x D)
- Titel: weight, Wert: approx. 16 kg
- Titel: sample dimension, Wert: 75 x 50 mm
- Titel: measuring frequencies, Wert: 1 MHz, 2 MHz selectable
- Titel: first measured value, Wert: approx. 10 ms after liquid contact
- Titel: measurement intervals, Wert: approx. 1 ms
- Titel: data structure, Wert: ASCII file
- Titel: supply voltage, Wert: 115-230 VAC, 50-60 Hz
- Downloads:
- Beschriftung : Leaflet (English), Link: images/stories/infomaterial/04_PDA.C02_alle_Module/01_PDA_MST/01_Leaflet/emtec_PDA.C02_MST_leaflet_en.pdf
- Beschriftung : Leaflet (French), Link: images/stories/infomaterial/04_PDA.C02_alle_Module/01_PDA_MST/01_Leaflet/emtec_PDA.C02_MST_leaflet_fr.pdf
- Beschriftung : Leaflet (Spanish), Link: images/stories/infomaterial/04_PDA.C02_alle_Module/01_PDA_MST/01_Leaflet/emtec_PDA.C02_MST_leaflet_es.pdf
- Beschriftung : Leaflet (Italian), Link: images/stories/infomaterial/04_PDA.C02_alle_Module/01_PDA_MST/01_Leaflet/emtec_PDA.C02_MST_leaflet_it.pdf
- Beschriftung : Leaflet (Turkish), Link: images/stories/infomaterial/04_PDA.C02_alle_Module/01_PDA_MST/01_Leaflet/emtec_PDA.C02_MST_leaflet_tr.pdf
- Beschriftung : Leaflet (Swedish), Link: images/stories/infomaterial/04_PDA.C02_alle_Module/01_PDA_MST/01_Leaflet/emtec_PDA.C02_MST_leaflet_se.pdf
- Beschriftung : Leaflet (Japanese), Link: images/stories/infomaterial/04_PDA.C02_alle_Module/01_PDA_MST/01_Leaflet/emtec_PDA.C02_MST_leaflet_jp.pdf
- Beschriftung : Leaflet (Chinese), Link: images/stories/infomaterial/04_PDA.C02_alle_Module/01_PDA_MST/01_Leaflet/emtec_PDA.C02_MST_leaflet_zh.pdf
- Beschriftung : Leaflet (Russia), Link: images/stories/infomaterial/04_PDA.C02_alle_Module/01_PDA_MST/01_Leaflet/emtec_PDA.C02_MST_leaflet_ru.pdf
- Beschriftung : Leaflet (Polish), Link: images/stories/infomaterial/04_PDA.C02_alle_Module/01_PDA_MST/01_Leaflet/emtec_PDA.C02_MST_leaflet_pl.pdf
- Beschriftung : Booklet (English), Link: images/stories/infomaterial/04_PDA.C02_alle_Module/01_PDA_MST/02_Booklet/01_EN/emtec_PDA_Penetration_Dynamics_Analyzer_MST_booklet_en.pdf
- Applikationsbeispiele inaktiv: Nein
- Applikationsbeispiele: The characterization of the surface pore structure helps to solve issues with the gluability
- Zubehör inaktiv: Nein
- Zubehör: OSB - Sample Preparation Device, SPM - Sample Preparation Machine, TCU - Temperature Control Unit
- verwandte Produkte: EST 12 - Surface and Sizing Tester, PDA.C 02 HVL - Module High Viscous Liquids, PDA.C 02 MSC - Module Standard Coating
- 360 Grad Bild (HTML Code): <a class="Magic360" data-options="columns: 73; rows: 1;"><img src="images/stories/produkte/SPM/360-webp/01.webp" /></a>
- Vorteile:
- Vorteil: efficiently
- Vorteil: user independent
- Vorteil: saves muscularity
- Vorteil: uniform
- Vorteil: time saving compared to manual preparation: up to 50% !
- Produktbeschreibung:
- Avoidance of measurement errors by varying handling:
constant compressing force - Thereby measuring results substantially more reproducible
- Adapter for various sample holders available
- Avoidance of measurement errors by varying handling:
- Anwender: Chemical suppliers, Paper machine builders, Paper producers , Paper converters, Board producers , Board converters, Corrugated board producers , Universities & Institutes
- Anwendungsgebiete: Process optimization, R&D, Incoming control, Quality assurance, Complaint management, Troubleshooting
- technische Daten:
- Titel: device dimensions, Wert: 40 x 25 x 40.5 cm (H x W x D)
- Titel: weight, Wert: 33.5 kg
- Applikationsbeispiele inaktiv: Ja
- Zubehör inaktiv: Ja
- verwandte Produkte: EST 12 - Surface and Sizing Tester, PDA.C 02 MST - Module Standard